  • VACUUM DEHYDRATION UNIT - 15 GPM
    VACUUM DEHYDRATION UNIT - 15 GPM

    VACUUM DEHYDRATION UNIT - 15 GPM

    P/N: FD15-R1

    The purpose of the FD-15 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and...

    SPECIFICATIONS
    Flow Rate:15 GPM Vacuum Pump Flow Rate:13 CFM Heater Capacity:18KW @ 15wsi Motors:3 HP, 480 VAC, 3 Phase; Other voltages are available Plumbing Requirements:Inlet: 1 1/2 inch FNPT; Outlet: 1 1/2 inch FNPT Approximate Dry Weight:1300 lbs Dimensions:54 inchL x 31 inchW x 78 inchH Start Up...
       
    D Series FilterCart - Simple and Powerful.
    P/N: FD15-R1

       
  • VACUUM DEHYDRATION UNIT - 5 GPM
    VACUUM DEHYDRATION UNIT - 5 GPM

    VACUUM DEHYDRATION UNIT - 5 GPM

    P/N: FD-5

    The purpose of the FD-5 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and...

    SPECIFICATIONS
    Flow Rate:5 GPM Vacuum Pump Flow Rate:13 CFM Heater Capacity:3KW @ 15wsi Motors:3 HP, 480 VAC, 3 Phase; Other voltages are available Plumbing Requirements:Inlet: 1 1/2 inch FNPT; Outlet: 1 1/2 inch FNPT Approximate Dry Weight:950 lbs Dimensions:44 inchL x 30.5 inchW x 68 inchH Start Up...
       
    Vacuum Dehydration System
    P/N: FD-5

       
  • 50 GPM Vacuum Dehydration 480V/3P/60Hz
    50 GPM Vacuum Dehydration 480V/3P/60Hz

    50 GPM Vacuum Dehydration 480V/3P/60Hz

    P/N: FD50-483-36-3

    The purpose of the FD-5 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and...

    SPECIFICATIONS
    Water and Particulate Removal System - 50 GPM- 4 (NEMA 4 Rated), Flow Rate - 50 GPM, Pre-Filtration - (Inlet Basket Strainer 20 Mesh), Filtration - Industry Standard 6 inch X 36 inch Housing, Heater - 66 kW Single Circulation Low Watt Density Heater NEMA 4 rated, Inlet/Discharge Size and Connections...
       
    Vacuum Dehydration System
    P/N: FD50-483-36-3

       
  • VACUUM DEHYDRATION UNIT - 15 GPM
    VACUUM DEHYDRATION UNIT - 15 GPM

    VACUUM DEHYDRATION UNIT - 15 GPM

    $61,068.75
    P/N: FD15-R2

    The purpose of the FD-15 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and...

    SPECIFICATIONS
    Flow Rate: 15 GPM, Vacuum Pump Flow Rate: 13 CFM, Heater Capacity: 18KW @ 15wsi, Motors: Electric, 480 VAC, 3 Phase; Other voltages are available, Plumbing: Inlet: 1 1/2 inch FNPT; Outlet: 1 1/2 inch FNPT, Approximate Dry Weight: 1300 lbs, Dimensions: 54 inchL x 31 inchW x 78 inchH,...
       
    Vacuum Dehydration System
    P/N: FD15-R2

    $61,068.75 
       
 
  •  
  •  
VACUUM DEHYDRATION UNIT - 15 GPM

VACUUM DEHYDRATION UNIT - 15 GPM

P/N: FD15-R1

The purpose of the FD-15 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and...

SPECIFICATIONS
Flow Rate:15 GPM Vacuum Pump Flow Rate:13 CFM Heater Capacity:18KW @ 15wsi Motors:3 HP, 480 VAC, 3 Phase; Other voltages are available Plumbing Requirements:Inlet: 1 1/2 inch FNPT; Outlet: 1 1/2 inch FNPT Approximate Dry Weight:1300 lbs Dimensions:54 inchL x 31 inchW x 78 inchH Start Up...
   
VACUUM DEHYDRATION UNIT - 5 GPM

VACUUM DEHYDRATION UNIT - 5 GPM

P/N: FD-5

The purpose of the FD-5 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and...

SPECIFICATIONS
Flow Rate:5 GPM Vacuum Pump Flow Rate:13 CFM Heater Capacity:3KW @ 15wsi Motors:3 HP, 480 VAC, 3 Phase; Other voltages are available Plumbing Requirements:Inlet: 1 1/2 inch FNPT; Outlet: 1 1/2 inch FNPT Approximate Dry Weight:950 lbs Dimensions:44 inchL x 30.5 inchW x 68 inchH Start Up...
   
50 GPM Vacuum Dehydration 480V/3P/60Hz

50 GPM Vacuum Dehydration 480V/3P/60Hz

P/N: FD50-483-36-3

The purpose of the FD-5 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and...

SPECIFICATIONS
Water and Particulate Removal System - 50 GPM- 4 (NEMA 4 Rated), Flow Rate - 50 GPM, Pre-Filtration - (Inlet Basket Strainer 20 Mesh), Filtration - Industry Standard 6 inch X 36 inch Housing, Heater - 66 kW Single Circulation Low Watt Density Heater NEMA 4 rated, Inlet/Discharge Size and Connections...
   
VACUUM DEHYDRATION UNIT - 15 GPM

VACUUM DEHYDRATION UNIT - 15 GPM

$61,068.75
P/N: FD15-R2

The purpose of the FD-15 Vacuum Dehydration System is to serve as an oil treatment system. By removing water (dissolved, emulsified and free), gasses and solid contaminants the oil can return to its original condition, and be reused in lubricating systems. Having clean, dry oil will allow hydraulic and...

SPECIFICATIONS
Flow Rate: 15 GPM, Vacuum Pump Flow Rate: 13 CFM, Heater Capacity: 18KW @ 15wsi, Motors: Electric, 480 VAC, 3 Phase; Other voltages are available, Plumbing: Inlet: 1 1/2 inch FNPT; Outlet: 1 1/2 inch FNPT, Approximate Dry Weight: 1300 lbs, Dimensions: 54 inchL x 31 inchW x 78 inchH,...